Ground-Water Information Center Organic Report
Site Name: MISSOULA COUNTY WQD WELL W131930D  Report Date: 4/29/2024

Location Information

Sample Id/Site Id 1303-19 / 151161 Sample Date 3/26/2013 10:50:00 AM
Location (TRS) 13N 19W 30 DDDA Agency/Sampler PRIVATE / UNKNOWN
Latitude/Longitude 46.851223465N -114.040343848W Field Number
Datum NAD83 Lab Name University of Montana
Altitude 3166.9 Analyst HL, MY
County/State MISSOULA / MT Sample Method/# Bottles
Site Type WELL Sample Type

Sample Information

Comparison Report
Type Analyte Value Units Qual Method MDL MRL Rec Ext Anl Staff
Fluoride 0.13 mg/L EPA 300.0 0.07 3/27/2013 HL
Chloride 7.1 mg/L EPA 300.0 0.6 3/27/2013 HL
N as Nitrite <0.1 mg/L EPA 300.0 0.1 3/27/2013 HL
N as Nitrate 0.77 mg/L EPA 300.0 0.15 3/27/2013 HL
Sulfate 17.7 mg/L EPA 300.0 0.6 3/27/2013 HL
Alkalinity (as CaCO3) 139 mg/L HATCH KIT TITRATION 10 3/29/2013 MY
Arsenic 2 ug/L EPA 6020 0.1 5/2/2013 HL
Barium ug/L EPA 6020 1 5/2/2013 HL
Calcium 39.1 mg/L EPA 6020 0.1 5/2/2013 HL
Cadmium ug/L EPA 6020 0.1 5/2/2013 HL
Chromium ug/L EPA 6020 1 5/2/2013 HL
Iron mg/L EPA 6020 0.005 5/2/2013 HL
Potassium 1.4 mg/L EPA 6020 0.5 5/2/2013 HL
Magnesium 11 mg/L EPA 6020 0.1 5/2/2013 HL
Manganese mg/L EPA 6020 0.0001 5/2/2013 HL
Sodium 5.8 mg/L EPA 6020 0.5 5/2/2013 HL
Nickel ug/L EPA 6020 0.5 5/2/2013 HL
Lead ug/L EPA 6020 0.1 5/2/2013 HL
Strontium ug/L EPA 6020 0.01 5/2/2013 HL
Zinc ug/L EPA 6020 0.1 5/2/2013 HL
Calcium 39.1 mg/L HL, MY
Magnesium 11 mg/L HL, MY
Sodium 5.8 mg/L HL, MY
Potassium 1.4 mg/L HL, MY
Chloride 7.1 mg/L HL, MY
Sulfate 17.7 mg/L HL, MY
Fluoride 0.13 mg/L HL, MY
Arsenic 2 ug/L HL, MY

Additional Information

Explanation: ND = Non-detect, value was below detection limit. NR = No Reading in GWIC
Disclaimer
These data represent the contents of the GWIC databases at the Montana Bureau of Mines and Geology at the time and date of the retrieval. The information is considered unpublished and is subject to correction and review on a daily basis. The Bureau warrants the accurate transmission of the data to the original end user. Retransmission of the data to other users is discouraged and the Bureau claims no responsibility if the material is retransmitted.